In NSW the planning legislation is clear - Granny Flats are a welcome addition to housing stock across the state. There is specific legislation, updated in November 2021 (the Housing SEPP) that sets out the guidelines for being able to build a Granny Flat with NO council approval, including what set backs are required for your lot size. Here we cover in detail how close you can build a Granny Flat to your boundary and to other structures on your site.
Complying development certification (CDC) is a faster approval process which ensures planning and environmental requirements are met through a set of prescribed approval conditions. An application for a CDC can be lodged with either a local council or an accredited certifier acting as the Certifying Authority. At Cubitt's we will work through how to build your Granny Flat with NO council approval to get a faster, smoother Granny Flat build. Here is some of what we will look at.
Zoning for Granny Flats
Granny Flats are permitted in residential zones (R1, R2, R3, R4 under a CDC and R5 under a DA). They may also be permitted in other zones under a council’s local environmental plan.
Classification of Granny Flats
A Granny Flat is a secondary dwelling. There can only be one principal dwelling and one secondary dwelling on each property. It is possible to build, two Granny Flats on a property however one of these would be classed as a main dwelling. The Housing SEPP provides for a new principal and secondary dwelling to be approved under a single complying development certificate.
Minimum Site Area for Granny Flats
The minimum site area is 450m2. If the land has an area less than 450m2, the development cannot be carried out as complying development regardless of whether it is attached to the principal dwelling. An exception to this is where a secondary dwelling is located entirely within an existing dwelling house.
Maximum Floor Area for Granny Flats
The maximum floor area for granny flat is not mentioned under this title. The maximum floor area, measure from the outside of the external wall is 60m2.
Building Clearance
1.8-metre clearance between class 1 buildings. You can build closer to class 1 buildings providing the relevant wall/s within 1.8 metres are fire rated. It is important to note that you can build as close as 1000mm to other structures such as garages providing garage is at least 1.8 meters away from primary dwelling.
Setbacks for Granny Flats
The setback of a site with a front boundary on a primary or parallel road is equal to the average of the front setbacks of the nearest two dwelling houses on the same road. These dwelling houses must be located within 40 metres of your lot. Otherwise, the setbacks are based on the lot size as shown in the diagrams below. There is a minimum setback of 3 metres from the rear boundary, 900mm from the side boundary and 4.5 metres from the front boundary. Select your lot size and click into the image to understand further detail on setbacks for your property size.
Need Some Expert Help?
Knowledge is non-negotiable. Our Design Consultant will measure out your site and help you fully understand the possibilities for your block, and be able to discuss in detail your options for a CDC or Development Application. When you’re planning to build, you want assurance that your site is suitable, and that you are not going to be impacted mid-build by unforeseen or surprise costs. We provide a thorough, free, upfront feasibility study for your Granny Flat which gives you an assured green light to build.
Free On-Site Assessment at Your Property
Interested in finding out how to make a positive investment from a Cubitt's Granny Flat or Home Extension? Get in touch for a no-obligation site inspection today.
We require your name, email and phone number to get back to you - and the more you can tell us about your build project, the more effectively our local teams can help.
Or call:
VIEW MORE OF OUR
Recent Blogs
Building Your Accommodation Business from Scratch in Rural NSW: A Comprehensive Guide
Whether you’re envisioning a cosy bed and breakfast or a cluster of serviced apartments, here’s a step-by-step guide to help you turn your dream of building an accommodation business into a prosperous reality.
What the Inland Code Means for Your Rural NSW Granny Flat Project
Are you considering adding a Granny Flat to your property in rural or regional New South Wales? The Inland Code does not permit complying development for the erection of secondary dwellings, commonly known as granny flats. This means that for the 69 Local Government Areas (LGAs) falling under the Inland Code, obtaining approval for a Granny Flat requires a Development Application (DA).
Unlocking Affordable Housing: Cubitt’s Calls on Premier Minns to Take a Cue from QLD
Cubitt’s Granny Flats advocates for affordable housing solutions, drawing inspiration from Queensland’s grant incentives for smaller builds.
ACT Land Zone RZ1 – You Can Now Build a Dual Occupancy up to 120m and Subdivide Your Block
ACT Canberra residential zone 1 (RZ1) blocks measuring 800 square meters or more are now eligible for the construction of two homes. Here is a quick FAQ on some elements of this change to help you start planning your ACT Dual Occupancy
End of Year Sale! $10k Cashback Offer When You Sign in 2023
To set up our schedule for 2024 we are offering an amazing $10k off your tender price while it’s still valid.
Top 50 NSW Suburbs With Granny Flat Potential
There could be a million residential properties across the nation with the potential to accommodate a Granny Flat. Is your suburb on the top 50 list?